From 1 December 2026, Australia's workplace exposure standards (WES) for airborne contaminants are replaced by workplace exposure limits (WEL). Until 30 November 2026, employers must still comply with the WES list. The change goes beyond a new name. Some limit values and notations change, some listings are merged, split, added or removed, and 33 substances move into a separate group of carcinogens with no individual limit.
Which changes matter depends on the chemicals your workers use or generate, so the practical response is a workplace-specific review. The WEL list is national, but it takes legal effect through each jurisdiction's WHS laws, and Victoria has a longer transition for 15 substances. This guide explains what to check and where to confirm it.
What Changes on 1 December 2026?
Exposure standards and limits set the airborne concentration of a substance or mixture that must not be exceeded. Safe Work Australia (SWA) says the new name communicates that the values are limits not to be exceeded and aligns Australia with international language. SWA also states that the rename itself does not change your obligations under the model WHS Regulations.
The list itself does change. It follows the first review of the exposure standards since 2003, and WHS ministers have agreed to adopt it from 1 December 2026. SWA's overview of the changes says changes can include:
- a higher or lower limit value
- a different type of exposure listing
- merged or split groups of contaminants
- renamed listings
- listings added or removed
- changed advisory notations
Until 30 November 2026, persons conducting a business or undertaking (PCBUs) must comply with the WES list. From 1 December 2026, they must ensure that no person at the workplace is exposed above the exposure limit in the WEL list.
The scheduled date and legal application are not always identical. SWA is not a regulator, and ministers agreed to a harmonised transition following implementation in the WHS laws of the Commonwealth, states and territories. WorkSafe Victoria shows why this matters. Most WEL apply there from 1 December 2026, but 15 substances have transition arrangements until 30 November 2029. Diesel particulate matter is one of them. SWA lists a new national limit of 0.01 mg/m³ from 1 December 2026, while Victoria applies an interim 0.1 mg/m³ for most industries until 2029. If you operate in more than one jurisdiction, check each one.

Which Exposure Limits and Health-Risk Notations Should Employers Check?
Start with SWA's WES and WEL comparison, which sets old and new values side by side. It covers only limits that are new or changing, so it is not a complete list. Use the current WEL list for full values, and match substances by chemical name and CAS number. Some listings have been renamed, merged or split. For example, several amyl acetate isomers now share one listing.
Limits take three forms: an eight-hour time-weighted average (TWA), a short-term exposure limit (STEL, averaged over 15 minutes) and a peak limit. Where gases and vapours show both ppm and mg/m³, SWA treats the ppm value as exact.
Toluene is a useful example. The comparison shows a WES of 50 ppm TWA and 150 ppm STEL. The WEL list shows 20 ppm TWA with an OTO notation, and the comparison shows no STEL. SWA has amended the list since the comparison was compiled, so confirm any figure against the current list before relying on it.
Advisory notations flag additional health risks. They sit alongside the limits and do not replace them.
|
Type of change |
What to check |
Follow-up |
|---|---|---|
|
Changed limit value |
Whether the TWA, STEL or peak limit is now lower or higher, and the units |
Compare against existing exposure data and reassess where results sit close to the new limit |
|
Limit type added or removed |
Whether a STEL or peak limit now applies, or no longer appears |
Review short-duration tasks, not only eight-hour averages |
|
Listing renamed, merged or split |
Whether your substance now sits under a different name, group or particle fraction |
Update the chemical register and SDS cross-references |
|
SEN split into DSEN and RSEN |
Whether the substance is a dermal (skin) sensitiser, a respiratory sensitiser or both |
Match controls to the route of exposure |
|
New OTO notation |
Whether the substance is ototoxic and workers are also exposed to noise |
Consider alongside noise controls, as SWA refers to the model Code of Practice on managing noise |
|
CARC notation removed |
Whether the substance may cause cancer |
Check the SDS or HCIS. The hazard has not gone away |
SWA explains that the CARC notation was removed because it describes a hazard classification and does not affect exposure levels. Removal does not mean a substance is no longer a cancer hazard.

What Remains Unchanged, and What Happens to NTGCs?
The nine chemicals. In 2024, ministers agreed to the revised limits except for nine chemicals: benzene, chlorine, copper, formaldehyde, hydrogen cyanide, hydrogen sulphide, nitrogen dioxide, respirable crystalline silica and titanium dioxide. These went through a further regulatory impact analysis. SWA's decision notice says a majority of ministers did not support new levels and requested further work. The exposure limits for these nine will not change on 1 December 2026. Treat any lower figures you see for them as proposals, not requirements.
NTGCs. SWA has identified 33 airborne contaminants as non-threshold genotoxic carcinogens. They include acrylamide, benzidine, 1,3-butadiene, ethylene oxide and vinyl chloride monomer. SWA says a practical, protective exposure level cannot be assigned for these because of limited data and the nature of their effects. From 1 December 2026 they have no exposure limits.
Where NTGCs are present, PCBUs must eliminate them, replace them with a safer alternative if possible, or reduce the risk so far as is reasonably practicable. SWA also says obligations under Schedules 10 and 14 of the model WHS Regulations continue where the NTGC used or generated is listed. These are model provisions, so confirm how your jurisdiction applies them.
The absence of an individual limit does not remove your duties. Even where a limit exists, SWA says it is not the dividing line between a healthy and unhealthy work environment, and risks must still be eliminated or minimised so far as is reasonably practicable.
What Should Employers Review Before the Transition?
Work through these five areas in order. Each builds the evidence for the next.

1. Audit the Hazardous Chemical Inventory
List the chemicals your workplace uses and the airborne contaminants your tasks generate, such as dust from cutting, fumes from welding or heating, and engine exhaust. Safety data sheets and HCIS show listed exposure limits. Match each substance by name and CAS number to the WEL list, and note whether it appears in SWA's changes document or the NTGC group.
2. Review Existing Risk Assessments
Prioritise assessments involving substances with a changed limit, a new listing, a changed notation or a different limit type. Then look at tasks with high exposure potential. Check whether any assessment relied on the old WES value, an old SEN or CARC notation, or a STEL that no longer applies.
3. Determine Whether Air Monitoring Is Needed
SWA says that if you are unsure whether exposure exceeds the WEL, you must conduct air monitoring. Under the model WHS Regulations, monitoring is required where you are not certain on reasonable grounds whether the airborne concentration exceeds the limit, or where it is necessary to determine whether there is a risk to health.
Existing results, process knowledge and evidence of effective controls can support certainty. Results measured against a higher limit may not settle the question under a lower one. A competent occupational hygienist can help plan sampling and interpret results, and SWA's guidance for PCBUs explains how to engage one.
4. Verify Control Measures and PPE
Start at the top of the hierarchy of control. Eliminate the contaminant where reasonably practicable, then substitute, isolate or enclose the process, use local exhaust ventilation (LEV), and apply administrative controls such as work procedures and reduced exposure time. Check that LEV and other controls perform as intended.

SWA says protection from respiratory protective equipment (RPE) can be taken into account when determining compliance with the WEL only after all reasonably practicable higher-order controls are in place and the RPE is worn correctly. A respirator is not a shortcut around better controls.
5. Update Records and Responsibilities
Assign an owner to each action, set review dates, and update risk assessments, chemical registers and procedures. Tell supervisors and workers what has changed in plain terms, and track corrective actions to completion. Check your regulator for record-keeping and training requirements that apply to your substances rather than assuming one rule applies everywhere.
How to Build a Practical WEL Review Plan
A simple sequence keeps the review manageable:
- Identify the substances and the tasks that generate exposure.
- Compare them against the applicable WES and WEL documents.
- Prioritise significant changes and higher-risk tasks.
- Review existing evidence and arrange air monitoring where needed.
- Improve controls, starting with elimination and substitution.
- Verify completion against your jurisdiction's requirements.
Each workplace needs a response proportionate to its substances, risks and existing controls. A small workshop using one solvent will have a shorter list than a manufacturer with dozens of listed contaminants. The aim is a documented, defensible position by 1 December, not identical paperwork everywhere.
Strengthen Your Workplace Hazard Identification and Risk Assessment Skills
Learn how to identify workplace hazards, assess risks and support more effective safety decisions.
Workplace Hazard Identification and Risk Assessment
Learn to identify workplace hazards and assess potential risks. Build practical knowledge to support safer workplace practices.
Conclusion: Prepare for the WES-to-WEL Transition
The WEL list is scheduled to replace the WES list on 1 December 2026. Some values, listings and notations change, the nine disputed chemicals stay as they are, and NTGCs move to an eliminate-or-minimise approach with no individual limit. Start by matching your inventory to the new list, then review risk assessments, monitoring needs and controls. Confirm jurisdiction-specific requirements with your regulator. This article is general information, not legal advice, and it does not replace specialist occupational hygiene advice.